Veyance Technologies, Inc.

Prospector™ BOP 3000

ProspectorBop3000_LG_con

Application:
3/8"-1" Blow Out Preventer hose is used for hydraulic connection between the well control equipment and the control system.

Construction:  

Inner Tube: Black Nitrile

Reinforcement: Two braids of high-tensile steel wire

Cover Compound: Pink Neoprene, wrapped finish


Temperature Range: -40ºF to 212ºF (-40ºC to 100ºC) 

PartHose Size IDHose ODMax. Working PressureMin. Bend RadiusMin. Burst PressureWeight
(lbs./ft.)
in.DINin.mmpsiMPain.mmpsiMPa
BOP-06  3/89.51.1128.8300020.761521200082.70.75
BOP-08  1/212.71.1930.2300020.782031200082.70.81
BOP-12  3/419.11.4937.8300020.7112791200082.71.22
BOP-16  125.41.8446.7300020.7153811200082.71.74

Download: BOP 3000 Hose Assembly Instructions (pdf)